Wednesday 15 May 2013

Avamar nodes Gen4s hardware

Avamar recently introduced the gen4s line to it's hardware based grids offering.
Here is the information I was able to gather so far regarding gen 4s hardware:

  • They have discontinued 1.3tb and 2.6Tb Nodes, they only make 2Tb, 3.9Tb and 7.8 Tb Nodes. The nodes are now manufatured by Intel, not Dell.
  • All Gen4S nodes require Avamar software version 6.1 SP1 or later
  • Gen4S nodes are compatible with existing Gen4 systems (provided nodes are running a compatible Avamar software version.



Hardware Specifications

M600 (2.0 TB licensed capacity)
Six 3.5” hard drives
Dual 750W power supplies
Eight 10/100/1000baseT GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system

M1200 (3.9 TB licensed capacity)
Six 3.5” hard drives
Dual 750W power supplies
Eight 10/100/1000baseT GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system

M2400 (7.8 TB licensed capacity)
Twelve 3.5” hard drives
One 2.5” SSD drive (internal mounting)
Dual 750W power supplies
Eight 10/100/1000baseT GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system

Avamar Business Edition/S2400 node (7.8 TB licensed capacity)
Available as single node server only
Eight 3.5” hard drives
One 2.5” SSD drive (internal mounting)
Dual 750W power supplies
Eight 10/100/1000baseT GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system
No replication required

Extended Retention ADS Gen4S Media Access node
Twelve 3.5” hard drives
One 2.5” SSD drive (internal mounting)
Dual 750W power supplies
Eight 10/100/1000baseT GbE ports
Two 8 Gbps fiber channel ports
Two 10 GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system
Note:
For installation instructions and hardware specifications for the Gen4S Media
Access node, see the

Avamar 6.1 Extended Retention Media Access Node Customer 
Hardware Installation Guide
(P/N 300-013-367).
ADS Accelerator node
Two 2.5” hard drives
Dual 750W power supplies
Four 10/100/1000baseT GbE ports
RMM4 management port
Avamar service port (hardware: NIC8, software: eth7)
SuSE Linux Enterprise Server v11 sp1 operating system


Source: "EMC Avamar Datastore Gen4S Single Node Customer Installation Guide"
P/N 300-999-651